Thermo Fisher Scientific ZO-1 Recombinant Mouse Monoclonal Antibody (ZO1-1A12), Alexa Fluor Plus 647
Alexa Fluor Plus 647 형광으로 표지된 ZO-1 재조합 마우스 단클론 항체. IHC, ICC/IF, Flow Cytometry에 사용 가능. 높은 신호 대 잡음비와 일관된 로트 간 품질을 제공하며, 세포 간 타이트 접합 연구에 적합.
- 카탈로그번호
- 740002MP647x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific ZO-1 Recombinant Mouse Monoclonal Antibody (ZO1-1A12), Alexa Fluor Plus 647
Thermo Fisher Scientific ZO-1 Recombinant Mouse Monoclonal Antibody (ZO1-1A12), Alexa Fluor Plus 647
Applications and Tested Dilution
| Application | Tested Dilution |
|---|---|
| Immunohistochemistry (Paraffin) (IHC (P)) | 1:100 |
| Immunocytochemistry (ICC/IF) | 1:2,000–1:4,000 |
| Flow Cytometry (Flow) | 0.063–0.5 µg/test |
Product Specifications
| Specification | Detail |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG1 |
| Expression System | Expi293 |
| Class | Recombinant Monoclonal |
| Type | Antibody |
| Clone | ZO1-1A12 |
| Immunogen | Human recombinant ZO-1 fusion protein (amino acids 334–634) |
| Conjugate | Alexa Fluor™ Plus 647 |
| Excitation/Emission Max | 658/675 nm |
| Form | Liquid |
| Concentration | 1.0 mg/mL |
| Purification | Protein A/G |
| Storage Buffer | Proprietary buffer, pH 6.5 |
| Contains | 0.008% Bromonitrodioxane, 0.008% Methylisothiazolone |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Wet ice |
| RRID | AB_3093163 |
Additional Formats
Product Specific Information
Alexa Fluor™ Plus recombinant antibodies utilize proprietary dye chemistry for enhanced fluorescence intensity and improved signal-to-noise ratio compared to standard Alexa Fluor conjugates. These recombinant antibodies ensure high specificity and lot-to-lot consistency.
Usage Note:
Before use, centrifuge the conjugate solution briefly and use only the supernatant to minimize nonspecific background staining caused by protein aggregates.
Applications Tested:
This ZO-1 antibody has been validated in:
- Immunohistochemistry of mouse testis tissue
- Immunocytochemistry and flow cytometry analysis of Caco-2 cells
Recommended concentration for flow cytometry: 0.063–0.5 µg per test (100 µL final volume, 10⁵–10⁸ cells/test).
Careful titration is recommended for optimal performance.
Excitation: 658 nm
Emission: 675 nm
Laser: Red Laser
Filtration: 0.2 µm post-manufacturing filtered
Target Information
ZO-1 forms complexes with ZO-2 or ZO-3 and associates with claudin, occludin, and F-actin at tight junctions, linking the actin cytoskeleton to the junctional complex. ZO-1 expression is reduced in many breast cancer lines. It may play a role in signal transduction at cell-cell junctions. Two transcript variants encoding distinct isoforms are known.
Diseases associated with ZO-1 dysfunction include Celiac Disease and Congenital Nephrotic Syndrome.
For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.