CacheBy
Restek Raptor Inert Biphenyl 2.7 µm 100 x 3.0 mm
AI 생성AI가 생성·보정한 이미지예요. AI는 실수할 수 있으니 실제 제품과 다를 수 있어요.
1 / 2

Restek Raptor Inert Biphenyl 2.7 µm 100 x 3.0 mm

상품 한눈에 보기

금속 민감성 화합물 분석에 최적화된 비활성 LC 컬럼. 비특이적 결합을 최소화해 감도와 피크 모양 개선. 마이코톡신 등 금속 민감성 분석에 이상적. 낮은 검출한계와 높은 재현성 제공. Restek Raptor Biphenyl 시리즈의 2.7 µm 코어셸 실리카 컬럼.

브랜드
Restek
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
Restek Raptor Inert Biphenyl, 2.7 µm, 100 x 3.0 mm HPLC Column판매 단위 pk ·
재고 확인 필요
1,516,510원VAT 포함 1,668,161원

Restek · Restek Raptor Inert Biphenyl 2.7 µm 100 x 3.0 mm

Overview

Features & Benefits

  • Inert LC column technology reduces nonspecific binding of chelating analytes, enabling sensitive analysis and smooth integration of peaks.
  • Ideal for the analysis of metal-sensitive compounds, such as mycotoxins.
  • Increased response and analyte recovery, allowing lower detection limits.
  • Improved peak shape without passivation or mobile phase additives.
  • Part of Restek’s Raptor Biphenyl column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.

Description

The new inert LC column technology helps laboratories improve analysis of metal-sensitive compounds.
A premium inert coating applied to the stainless-steel surface reduces nonspecific binding of chelating analytes, enabling sensitive analysis and smooth peak integration.
Combined with Restek’s selective stationary phases, these inert LC columns are ideal for the analysis of metal-sensitive compounds such as mycotoxins.

Column Characteristics

Parameter Specification
Stationary Phase Category Phenyl (L11)
Ligand Type Biphenyl
Particle Type Superficially porous particle (SPP or “core-shell”) silica
Particle Size 1.8 µm, 2.7 µm, or 5 µm
Pore Size 90 Å
Carbon Load 7% (1.8 µm or 2.7 µm), 5% (5 µm)
End-Cap Yes
Surface Area 125 m²/g (1.8 µm); 130 m²/g (2.7 µm); 100 m²/g (5 µm)
Parameter Specification
pH Range 2.0 – 8.0
Maximum Temperature 80 °C
Maximum Pressure 1034 bar / 15,000 psi (1.8 µm)
600 bar / 8,700 psi (2.7 µm)
400 bar / 5,800 psi (5 µm)
Recommended Max Pressure (1.8 µm) 830 bar / 12,000 psi for maximum lifetime

Properties

  • Increased retention for dipolar, unsaturated, or conjugated solutes.
  • Enhanced selectivity when used with methanolic mobile phase.
  • Ideal for increasing sensitivity and selectivity in LC-MS analyses.

When to Switch to a Biphenyl Column

  • Limited selectivity is observed on a C18 column.
  • Increased retention of hydrophilic aromatics is needed.

Specifications

Catalog No. Product Name
9309A1E-T Raptor Inert Biphenyl, 2.7 µm, 100 x 3.0 mm HPLC Column

Restek 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.