Thermo Fisher Scientific Pierce Silver Stain Kit, 1 L
상품 옵션 정보 | ||||||||
---|---|---|---|---|---|---|---|---|
카탈로그 번호 | CAS 번호 | 설명 | 상태 | 단위 | 판매가 | 할인가 | 가격(VAT포함) | 수량 / 장바구니 / 찜 |
24612 | - | Thermo Fisher Scientific 24612 Pierce Silver Stain Kit, 1 L Each pk | 재고문의 | pk | 291,000원 | - | 320,100원 | |
24612X3 | - | Thermo Fisher Scientific 24612X3 Pierce Silver Stain Kit, 3 x 1 L Each pk | 재고문의 | pk | 0원 | - | 0원 |
다른 상품 둘러보기
Thermo Scientific™
Pierce™ Silver Stain Kit
The Pierce Silver Stain Kit is a rapid, ultra-sensitive, and versatile silver stain system for protein detection in polyacrylamide gels,자세히 알아보기
The Pierce Silver Stain Kit is a rapid, ultra-sensitive, and versatile silver stain system for protein detection in polyacrylamide gels, yielding consistent and reliable results. It is a metallic silver (Ag) protein stain that yields a remarkably clear and uniform gel background. In standard mini gels, proteins are detectable at greater than 0.25 ng per band or spot. The protocol has been optimized for flexibility by allowing short or overnight gel fixation and staining steps without affecting staining performance (sensitivity or clarity). A short (one-minute) sensitization step, performed after gel fixation, yields results that are free of the characteristically dark or blotchy backgrounds often seen with homemade or other commercially available silver stains. This feature is beneficial when performing densitometric analysis of silver stained gels.
Features:
• Sensitivity—detect proteins at 0.25 ng
• Protocol—gel staining can be performed within 5 min to 20 hrs, depending on desired sensitivity
• Gel-compatibility—staining performance is very good with a variety of commercial precast mini-gels and SDS-PAGE buffer-systems
• Workflow-compatible—mild chemical formulation ensures compatibility with mass spectrometry, sequencing, and other downstream procedures that depend on destaining and protein recovery
Silver staining methods generally use either glutaraldehyde or formaldehyde, which cause some covalent crosslinking of protein to each other and the gel matrix. To the extent that this crosslinking occurs, extraction or elution of protein from the gel will be inhibited. Pierce Silver Stain uses formaldehyde in the stain and developer working solutions, but the concentration is low enough that irreversible protein crosslinking is minimized.
사양
검출 위치In-Gel Detection
검출 방법Colorimetric
라벨 또는 염료Silver
제품 유형Stain Kit
제품라인Pierce™
수량1 L
타겟 분자Protein
Unit SizeEach
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|