CacheBy
Thermo Fisher Scientific DHX Heat Exchanger BioProcess Container (BPC), ASI 26/77 film, ReadyMate connections, four 6-L BPCs
AI 생성AI가 생성·보정한 이미지예요. AI는 실수할 수 있으니 실제 제품과 다를 수 있어요.
1 / 2

Thermo Fisher Scientific DHX Heat Exchanger BioProcess Container (BPC), ASI 26/77 film, ReadyMate connections, four 6-L BPCs

상품 한눈에 보기

Thermo Scientific DHX Heat Exchanger BPC는 4개의 6L 단일 사용 바이오프로세스 컨테이너로 구성된 2D 시스템으로, ASI 26/77 필름과 ReadyMate 커넥션을 사용합니다. 세척 불필요, 오염 위험 감소, 유지보수 비용 절감, cGMP 공정용으로 적합합니다.

판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 05. 오전 11:43
Thermo Fisher Scientific DX00009I DHX Heat Exchanger BioProcess Container (BPC), ASI 26/77 film, ReadyMate connections, four 6-L BPCs Each pk판매 단위 pk ·
재고 확인 필요
847,700원VAT 포함 932,470원

Thermo Fisher Scientific · Thermo Fisher Scientific DHX Heat Exchanger BioProcess Container (BPC), ASI 26/77 film, ReadyMate connections, four 6-L BPCs

Thermo Fisher Scientific DHX Heat Exchanger BioProcess Container (BPC)

The Thermo Scientific™ DHX™ Heat Exchanger Single-Use BioProcess Container (BPC) is a 2D system consisting of four 6 L BPCs without drain. It is composed of Thermo Scientific™ ASI™ 26/77 Polyethylene Film, with interconnecting TPE tubing and ReadyMate DAC end connections.
The DHX Heat Exchanger and DHX BPC each feature a serpentine pattern, creating a sterile fluid path for the process fluid. The BPC fits tightly between the stainless steel DHX Heat Exchanger plate system, and after loading, no further operator interaction is required. The customer has the option of utilizing up to 4 BPCs in the DHX unit.

Features

  • Eliminates post-use cleaning steps required with reusable containers, helping reduce cross-contamination risks
  • Provides sterile processing environment without the cost and time of CIP/SIP sterilization
  • Minimizes bioburden by addressing weak points in CIP or sanitation processes
  • Reduces maintenance and life cycle cost due to its unique design
  • Increases volume capacity via parallel connection between DHX units

Applications

  • cGMP commercial and clinical biotherapeutics, vaccines, and other biologic processes
  • Upstream applications: media hold, harvest cooling, harvest hold
  • Downstream applications: harvest hold, buffers, protein purification, bulk drug substance

Specifications

항목 내용
용량(미터법) 24 L
구성 4 × 6 L BPCs
치수 Each BPC: 62.2 cm × 61.9 cm (24.5 in × 24.4 in)
용도(장비) DHX1001
필름 설명 ASI™ 26/77
물질 Polyethylene
Tubing Style TPE
포트 세부 정보 ReadyMate DAC connectors
외부 포장 Two 4-mil poly bags
보호용 내부 포장 Protective material around rough areas
멸균 방법 Gamma Irradiated
배송 조건 Room Temperature
제품라인 DHX
Unit Size Each

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0