CacheBy
Thermo Fisher Scientific SCN11A Polyclonal Antibody
원본

Thermo Fisher Scientific SCN11A Polyclonal Antibody

상품 한눈에 보기

SCN11A 단백질을 인식하는 Thermo Fisher Scientific의 Rabbit Polyclonal Antibody로, WB, IHC(F), ICC/IF에 사용 가능. Lyophilized 형태로 제공되며 -20°C 보관. 연구용으로만 사용.

카탈로그번호
PA577733
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 07. 28. 오후 03:40
Thermo Fisher Scientific PA577733 SCN11A Polyclonal Antibody 50 ul pk판매 단위 pk ·
재고 확인 필요
949,900원VAT 포함 1,044,890원

Thermo Fisher Scientific · Thermo Fisher Scientific SCN11A Polyclonal Antibody

Applications

Application Tested Dilution Notes
Western Blot (WB) 1:200
Immunohistochemistry (Frozen) (IHC (F)) Assay-Dependent
Immunocytochemistry (ICC/IF) 1:500

Product Specifications

Specification Description
Host / Isotype Rabbit / IgG
Class Polyclonal
Type Antibody
Immunogen Peptide CNGDLSSLDVAKVKVHND, corresponding to amino acid residues 1748–1765 of rat Nav 1.9
Conjugate Unconjugated
Form Lyophilized
Concentration 0.8 mg/mL
Storage Conditions -20°C
Shipping Conditions Wet ice
RRID AB_2736563

Product Specific Information

Product is shipped at room temperature as a lyophilized powder and should be stored at -20°C upon receipt.
Reconstitute using 50 µL deionized water.

Target Information

Epithelial sodium channels are amiloride-sensitive members of the Degenerin/epithelial sodium channel (Deg/ENaC) superfamily of ion channels. Members of this superfamily share organizational similarity with two short intracellular amino and carboxyl termini, two short membrane-spanning segments, and a large extracellular loop with a conserved cysteine-rich region.

There are three homologous isoforms of the ENaC (alpha, beta, and gamma) protein. ENaC in the kidney, lung, and colon plays an essential role in trans-epithelial sodium and fluid balance. It mediates aldosterone-dependent sodium reabsorption in the distal nephron of the kidney, thus regulating blood pressure. ENaC is thought to be regulated, in part, through association with the cystic fibrosis transmembrane conductance regulator (CFTR) chloride ion channel.

Gain-of-function mutations in beta- or gamma-ENaC can cause severe arterial hypertension (Liddels syndrome), and loss-of-function mutations in alpha- or beta-ENaC cause pseudohypoaldosteronism (PHA-1).

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

제품 이미지

(이미지 없음)

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.