Thermo Fisher Scientific Easy-Titer Human IgG (H+L) Assay Kit

상품 옵션 정보
카탈로그 번호CAS 번호설명상태단위판매가할인가가격(VAT포함)수량 / 장바구니 / 찜
23310-Thermo Fisher Scientific 23310 Easy-Titer Human IgG (H+L) Assay Kit Each pk재고문의pk763,000-839,300

Thermo Scientific™

Easy-Titer™ Human IgG (H+L) Assay Kit

The Thermo Scientific Easy-Titer Human IgG (H+L) Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by자세히 알아보기

The Thermo Scientific Easy-Titer Human IgG (H+L) Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by an easy and rapid microagglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer). This kit is specific for human IgG and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins. It is sensitive, requiring very small sample volumes. Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately).

General features of Easy-Titer Antibody Assay Kits:

Antibody-based specificity—measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration
Faster and easier than ELISA—three-component, homogenous assay; 10 minutes total incubation time
No special equipment needed—uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm)
Sensitive—assay range (standard curve) 8 to 500 ng/mL; use sample at 15 to 300 ng/mL for optimal results
Reproducible—coefficient of variation < 5%; error depends on dilution and pipetting technique
Antibody standards sold separately—see product list for suggested products; use any antibody standard with proper target identity and known concentration (greater than 10 μg/mL)
Kits for five popular targets—choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody

Easy-Titer Assay Kits detect and measure specific target antibodies using agglutination of microspheres that are coated (sensitized) with the specific anti-IgG or IgM polyclonal antibodies. In the appropriate aqueous buffer (supplied in kit), the monodispersed antibody-coated microspheres (> 1 μM diameter) have highest absorptivity (λ-max) to incident light having a wavelength (340nm) that is equal to approximately half their diameter. When sample is added, two or more microspheres bind to each antibody target via their coated specific polyclonal antibodies, and this agglutination into effectively larger apparent spheres results in proportional decrease in absorptivity (lower absorbance).

Typical microagglutination assays depend on a change in light-scattering and corresponding change in transmittance, to which absorbance is inversely related. Easy-Titer Assay Kits use a special dilution buffer whose refractive index eliminates the effect of light-scattering on the monodispersed microspheres for the measurement wavelength used. Because of this, the final 10- to 20-fold dilution of the sample for use in the assay must be done using the Dilution Buffer supplied in the kit.

Easy-Titer Antibody Assays are faster and easier than ELISA:
• Prepare standards (5 to 500 ng/mL) by diluting purified antibody in Kit Dilution Buffer.
• Prepare samples by diluting in Dilution Buffer to within assay range (8 to 500 ng/mL).
• Vortex vial of microsphere beads to create homogeneous suspension.
• Pipette 20 μL of bead suspension and 20 μL of each sample and standard into 96-well microplate wells.
• Incubate microplate for 5 minutes with vigorous mixing.
• Add 100 μL of Kit Blocking Reagent.
• Incubate microplate for 5 minutes with vigorous mixing.
• Measure absorbance on standard plate reader (340nm or 405nm).
• Plot standard curve and interpolate samples to determine concentration.

Related Products
Easy-Titer™ Mouse IgG Assay Kit
Easy-Titer™ Rabbit IgG Assay Kit
Easy-Titer™ Human IgG (gamma chain) Assay Kit
Easy-Titer™ Human IgM Assay Kit

사양

설명Easy-Titer Human IgG (H + L) Assay Kit

용도(애플리케이션)Solution-based Detection, Absorbance

용도(장비)Spectrophotometer, Microplate Reader

수량96 Tests

어세이Protein Quantitation Assay, Isotyping Assay, Immunoassay

검출 방법Colorimetric

제품라인Easy-Titer™

타겟 특이도Human IgG

Unit SizeEach


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
  • - 상품 결제 후 최대 60일 이내 제공 완료
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0