
Thermo Fisher Scientific EcoRII (10 U/μL)
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Thermo Scientific™
EcoRII (10 U/μL)
5↓C C W G G 3
3G G W C C ↑ 5
Thermo Scientific EcoRII restriction enzyme recognizes ^CCWGG자세히 알아보기
**
5` | ↓ | C | C | W | G | G | 3` | |||
3` | G | G | W | C | C ↑ | 5` |
**
Thermo Scientific EcoRII restriction enzyme recognizes ^CCWGG sites and cuts best at 37°C in O buffer. See Reaction Conditions for Restriction Enzymes for a table of enzyme activity, conditions for double digestion, and heat inactivation for this and other restriction enzymes. Isoschizomers: AjnI, BseBI, Bst2UI, BstNI, BstOI, Psp6I, PspGI.
Thermo Scientific conventional restriction endonucleases are a large collection of high quality restriction enzymes, optimized to work in one of the buffers of the Five Buffer System. In addition, the universal Tango buffer is provided for convenience in double digestions. All of the enzymes exhibit 100% activity in the recommended buffer and reaction conditions. To ensure consistent performance, Thermo Scientific restriction enzyme reaction buffers contain premixed BSA, which enhances the stability of many enzymes and binds contaminants that sent in DNA preparations.
Features
• Superior quality—stringent quality control and industry leading manufacturing process
• Convenient color-coded Five Buffer System
• Includes universal Tango buffer for double-digestions
• BSA premixed in reaction buffers
• Wide selection of restriction endonuclease specificities
Applications
• Molecular cloning
• Restriction site mapping
• Genotyping
• Southern blotting
• Restriction fragment length polymorphism (RFLP)
• SNP
Note: At least two copies of EcoRII recognition site are required for efficient cleavage. For cleavage of DNA substrates with only one copy of recognition site MvaI, neoschizomer of EcoRII is recommended. EcoRII may remain associated with the cleaved DNA. This may cause DNA band shifting during electrophoresis. To avoid atypical DNA band patterns, use the 6X DNA Loading Dye & SDS Solution for sample preparation, or heat the digested DNA in the presence of SDS prior to electrophoresis. Assayed using pBR322 DNA (dcm-). EcoRII is blocked by overlapping dcm methylation. To avoid dcm methylation, use a dam-, dcm- strain, such as GM2163.For methylation sensitivity, refer to product specifications.
사양
농도10 U/μL
메틸화 민감도Dcm Methylation-Sensitive, Not Dam Methylation-Sensitive, Not CpG Methylation-Sensitive
효소EcoRII
함께 사용가능한 버퍼10X Buffer O
열 불활성화에 대한 민감성Yes
최적 반응 온도37°C
Type IIS RENo
수량200 units
제품 유형Restriction Enzyme
연구 카테고리Traditional Cloning
Unit SizeEach
🏷️Thermo Fisher Scientific 상품 둘러보기
동일 브랜드의 다른 상품들을 확인해보세요

Thermo Fisher Scientific
Thermo Fisher Scientific SmoI (SmlI) (10 U/μL)
179,900원

Thermo Fisher Scientific
Thermo Fisher Scientific LguI (SapI) (5 U/μL), 100 units
119,300원

Thermo Fisher Scientific
Thermo Fisher Scientific EcoRII (10 U/μL)
196,500원

Thermo Fisher Scientific
Thermo Fisher Scientific AjiI (BmgBI) (5 U/μL)
262,000원

Thermo Fisher Scientific
Thermo Fisher Scientific CseI (HgaI) (5 U/μL)
142,800원
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제수단 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|