Thermo Fisher Scientific Pierce Dye Removal Columns
상품 옵션 정보 | ||||||||
---|---|---|---|---|---|---|---|---|
카탈로그 번호 | CAS 번호 | 설명 | 상태 | 단위 | 판매가 | 할인가 | 가격(VAT포함) | 수량 / 장바구니 / 찜 |
22858 | - | Thermo Fisher Scientific 22858 Pierce Dye Removal Columns Each pk | 재고문의 | pk | 239,000원 | - | 262,900원 |
다른 상품 둘러보기
Thermo Scientific™
Pierce™ Dye Removal Columns
Thermo Scientific Pierce Dye Removal Columns effectively bind to unconjugated fluorescent dye molecules from protein solutions to rapidly purify fluorescent자세히 알아보기
Thermo Scientific Pierce Dye Removal Columns effectively bind to unconjugated fluorescent dye molecules from protein solutions to rapidly purify fluorescent conjugated antibodies and other proteins after labeling reactions.
These Fluorescent Dye Removal Columns enable fast and efficient removal of non-reacted fluorescent dyes from protein labeling reactions. Removing excess dye after a labeling reaction is often difficult and time-consuming but is essential for accurate determination of dye-to-protein ratios. The dye removal resin in this kit is highly specialized to produce exceptional protein recoveries while effectively removing non-conjugated dye. Using the appropriate amount of resin and buffer conditions, almost any fluorescent dye can be removed with this kit.
Features of Dye Removal Columns:
• Fast—removes free, unconjugated dye from labeled protein solutions in less than a minute
• Specific—purification resin provides outstanding conjugate recovery (75 to 95%)
• Customizable—separate resin and microcentrifuge columns allow optimization for different dyes and concentrations of sample
• Sample-friendly—processing results in minimal sample dilution
This product has been used successfully to remove excess, unconjugated fluorescein, rhodamine and DyLight Dyes from antibodies following labeling reactions. Samples with dyes in the green spectrum, such as Dylight 549 and rhodamine, might require double processing because they require a high molar excesses for labeling. When using fluorescent dyes other than those described in the product instructions, the ratio of resin to protein/dye mixture will require optimization.
사양
형식Kit, Microcentrifuge, Spin Column
수량10 columns, 5 mL resin
제품 유형Dye Removal Column
타겟Fluorescent Dye Removal
제품라인Pierce™
Unit SizeEach
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|