Thermo Fisher Scientific PBFI, AM, cell permeant - Special Packaging
상품 옵션 정보 | ||||||||
---|---|---|---|---|---|---|---|---|
카탈로그 번호 | CAS 번호 | 설명 | 상태 | 단위 | 판매가 | 할인가 | 가격(VAT포함) | 수량 / 장바구니 / 찜 |
P1267MP | - | Thermo Fisher Scientific P1267MP PBFI, AM, cell permeant - Special Packaging Each pk | 재고문의 | pk | 1,191,000원 | - | 1,310,100원 |
Invitrogen™
PBFI, AM, cell permeant - Special Packaging
PBFI is a potassium-sensitive molecule used measure intracellular K+ fluxes in animal cells and in plant cells and vacuoles. Although자세히 알아보기
PBFI is a potassium-sensitive molecule used measure intracellular K+ fluxes in animal cells and in plant cells and vacuoles. Although the selectivity of PBFI for K+ is less than that of calcium indicators such as fura-2, it is sufficient for the detection of physiological concentrations of K+ in the presence of other monovalent cations. The spectral response of PBFI upon ion binding permit excitation ratio measurements, and this indicator can be used with the same optical filters and equipment used for fura-2.
Fluorescent Ion Indicators Specifications:
• Label (Ex/Em): PBFI (∼340,380/500 nm)
• Lyophilized product may be dissolved in DMSO for use
• Product is typically loaded into cells by adding the dissolved indicator to medium containing cells
Selectivity Considerations and Cell Loading Strategies
The Kd of PBFI for K+ is strongly dependent on whether Na+ is present, with a value of 5.1 mM in the absence of Na+ and 44 mM in solutions with a combined Na+ and K+ concentration of 135 mM (which approximates physiological ionic strength). In buffers in which the Na+ is replaced by tetramethylammonium chloride, the Kd of PBFI for K+ is 11 mM; choline chloride and N-methylglucamine are two other possible replacements for Na+ in the medium. Although PBFI is only 1.5-fold more selective for K+ than for Na+, this selectivity is often sufficient because intracellular K+ concentrations are normally about 10 times higher than Na+ concentrations.
PBFI is available as both cell-impermeant acid salt (P1265MP) and as cell-permeant acetoxymethyl (AM) esters (P1267MP). The anionic acid forms can be loaded into cells using our Influx™ pinocytic cell-loading reagent (I14402, Chelators, Calibration Buffers, Ionophores and Cell-Loading Reagents—Section 19.8), or by microinjection, patch-pipette infusion or electroporation. For AM ester loading (Loading and Calibration of Intracellular Ion Indicators—Note 19.1), addition of the Pluronic™ F-127 (P3000MP, P6866, P6867) or PowerLoad™ (P10020) dispersing agents as well as relatively long incubation times—up to four hours—are typically necessary.
Find Fluorescent Indicators for Na+ and K+
We offer a number of fluorescent indicators for measuring Na+ and K+. Review Fluorescent Na+ and K+ Indicators—Section 21.1 in the Molecular Probes™ Handbook for more information on these products.
For Research Use. Not for human or animal therapeutic or diagnostic use.
사양
검출 방법Fluorescence
용도(애플리케이션)Cell Viability and Proliferation
용도 (장비)Fluorescence Microscope
제품 유형PBFI AM
염료 유형Potassium Indicator
수량20 x 50 μg
배송 조건Room Temperature
Unit SizeEach
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|